Remote access via Gira S1 or ise smart connect KNX remote access
Launching Gira X1 app => connection established automatically in the background
No more complex VPN setup
No configuration of customer router
Solution to IPV6 issues.
Dimming (RGBW)
Absolute RGB dimming function with five favourite settings
Absolute RGBW dimming function with five favourite settings
Dimming (Tunable White)
Absolute Tunable White dimming function with five favourite settings
Air conditioner control for KNX gateways with five favourite settings
RTC auxiliary unit for sauna function
Audio control with media support and playlists
Button (Press/Release)
Press for on / release for off
Press for off / release for on
Demo mode:
Key functions of the app can be experienced even without Gira X1 hardware
Available for iOS and Android
PIN protection for system menu
System menu settings protected from unauthorised access
Status view – folder view
Functions with status display
Diagnostic page
Mandatory authentication with user name and password
General improvements
Trades
Room name added to functions
Dimmer and dimmer (step size) functions consolidated
Camera
Function with and without password
Start button removed
Heating and cooling (On/Off)
Ability to switch between heating and cooling mode in the Gira X1 app
Change operating mode is no longer required field
RTC auxiliary unit ON/OFF
Signed and unsigned 32-bit value transmitter
Value transmitter with keypad input for value range with more than three digits
Value transmitter (all function templates)
Timer available in the Gira X1 app
Errors corrected
The scrolling functions of the value transmitter did not stop at the target value when operated quickly.
Symbols selected in GPA were not displayed in the Gira X1 app in a few cases.
After restarting X1, it was possible that the configuration of the Gira X1 app would not load.
The heating function could no longer be used in the Gira X1 App outside of the incorrectly configured min./max. values.
Logic functions are read from the bus even without activating the "read from the KNX bus" parameter
The "Delete all data points" function is missing from the scene set.
Known errors
The sending physical KNX address is missing in the line scan.
Data point of the camera is additionally toggled during switch-off.
The discharging function of the ETS has no effect on the additional physical addresses.
The KNX group address data point time (DPT 10.001) is sent with a random day of the week.
To perform the update the Gira Project Assistant V 2.4 is required. It is recommended to always use the latest available GPA version. Please follow the instructions in the enclosed documentation.